ADVANTEC
- 첨부파일0
- 추천수
- 0
- 조회수
- 5538
내용
ADVANTEC Membrane filter-Cellulose Acetate
◈ Product Information
• Composition : Mixture of cellulose triacetate and diacetate
• Characteristics : Low static charge and high strength
• Autoclavable : Withstands autoclaving temperatures up to 130°C without adversely affecting bubble point,
flow rate or microbiological recovery
• Clean : Lowest aqueous extractables (0.1 wt%) of all Advantec membranes
• Relative to MCE (Mixed Cellulose Esters, Nitrocellulose):
– improved solvent resistance to low molecular weight alcohols
– better heat resistance
– lower protein binding
► Applications
• Enhanced recovery of fastidious gram positive organisms
• Filtration of enzyme solutions
• Diagnostic cytology
• Receptor binding studies
Note: Should not be prewet prior to loading into a holder and autoclaving.
► Specifications
• Wetting time: <3 seconds to wet a 47 mm diameter disc with aqueous 1% methylene blue
• Refractive index = 1.47
• Maximum operating temperature = 180°C
• Ash content 1.5–3.5 µg/cm2
Definitions:
*1. Bubble point is the minimum pressure required to force air
through a membrane which has been prewet with water
*2. Flow Rate indicates initial flow rate at 10 psi using a KGS 47 filter holder
Water: using water prefiltered to 0.1 µm pore size
Air: using 25°C air at 10 psi
*3. Porosity refers to the percent open area
► Metal Content of White Plain Cellulose Acetate Membrane Filters (ppm)
◈ Ordering Information
ADVANTEC Membrane filter-Cellulose Acetate
◈ Product Information
• Composition : Mixture of cellulose triacetate and diacetate
• Characteristics : Low static charge and high strength
• Autoclavable : Withstands autoclaving temperatures up to 130°C without adversely affecting bubble point,
flow rate or microbiological recovery
• Clean : Lowest aqueous extractables (0.1 wt%) of all Advantec membranes
• Relative to MCE (Mixed Cellulose Esters, Nitrocellulose):
– improved solvent resistance to low molecular weight alcohols
– better heat resistance
– lower protein binding
► Applications
• Enhanced recovery of fastidious gram positive organisms
• Filtration of enzyme solutions
• Diagnostic cytology
• Receptor binding studies
Note: Should not be prewet prior to loading into a holder and autoclaving.
► Specifications
Pore Size
(µm) |
Bubble Point *1 | Flow Rate *2 | Porosity *3 (%) | Thickness
(µm) |
||
MPa | psi | Water
(mL/min/cm2) |
Air
(L/min/cm2) |
|||
0.20 | ≥0.25 | ≥37.1 | 16 | 2 | 66 | 125 |
0.45 | ≥0.17 | ≥25.9 | 35 | 4 | 68 | 125 |
0.80 | ≥0.068 | ≥10.0 | 160 | 14 | 72 | 125 |
3.00 | ≥0.034 | ≥5.0 | 500 | 54 | 78 | 135 |
• Refractive index = 1.47
• Maximum operating temperature = 180°C
• Ash content 1.5–3.5 µg/cm2
Definitions:
*1. Bubble point is the minimum pressure required to force air
through a membrane which has been prewet with water
*2. Flow Rate indicates initial flow rate at 10 psi using a KGS 47 filter holder
Water: using water prefiltered to 0.1 µm pore size
Air: using 25°C air at 10 psi
*3. Porosity refers to the percent open area
► Metal Content of White Plain Cellulose Acetate Membrane Filters (ppm)
Al | <5.0 | K | 2.0 | Ni | <0.5 |
Ca | 36.4 | Li | <0.5 | Pb | <0.5 |
Cd | <0.1 | Mg | 1.9 | Si | 7.8 |
Cr | 2.2 | Mn | <0.5 | Sn | <0.5 |
Cu | 1.2 | Mo | <0.5 | Ti | <5.0 |
Fe | 1.6 | Na | 5.9 | Zn | 0.6 |
◈ Ordering Information
Pore Size
(µm) |
Diameter | ||||||
13 mm | 25 mm | 37 mm | 47 mm | 90 mm | 142 mm | 293 mm | |
package of 100 discs(NON-STERILE) | package of 25 discs(NON-STERILE) | ||||||
0.20 | C020A013A | C020A025A | C020A037A | C020A047A | C020A090C | C020A142C | C020A293C |
0.45 | C045A013A | C045A025A | C045A037A | C045A047A | C045A090C | C045A142C | C045A293C |
0.80 | C080A013A | C080A025A | C080A037A | C080A047A | C080A090C | C080A142C | C080A293C |
3.00 | C300A013A | C300A025A | C300A037A | C300A047A | C300A090C | C300A142C | C300A293C |
0
0
게시물수정
게시물 수정을 위해 비밀번호를 입력해주세요.
댓글삭제게시물삭제
게시물 삭제를 위해 비밀번호를 입력해주세요.