GC
4
Agilent Ferrules
Ferrules
◈ Product Information
Using the wrong ferrule or a worn-out ferrule to seal your column connection can result in inconsistent and unreliable chromatography. An improper ferrule can cause leaks which allow air and other contaminants to enter the instrument through the column seal, causing major interference with column and detector performance. For optimum performance, ferrules should be replaced every time the column is replaced and when performing column maintenance.
► Graphite (100%) Ferrules
• General purpose for capillary columns
• Suitable for FID, NPD, and ECD
• Recommended for high temperature and cool on-column applications
• Material is free of sulfur and other contaminants
• Can be reused or removed easily
• Proper installation requires a finger-tight turn on the nut, then an additional 1/4 turn with a wrench
• Not for use with MS or oxygen sensitive detectors
► Vespel/Graphite (85%/15%) Ferrules
• General purpose for capillary columns
• Recommended for MS or oxygen sensitive detectors
• Also compatible with other detectors like FID and NPDs
• Most reliable leak free connection
• Proper installation requires a finger-tight turn on the nut, then an additional 1/4 turn with a wrench
• Ferrule hole MUST match the column OD exactly to ensure a leak-free seal
• Not reusable
► Vespel (100%) Ferrules
• Isothermal operation
• Can be reused or removed easily
• Excellent sealing material when making metal or glass connections
• Long lifetime
◈ Ordering Information Ferrule ID(mm) Column ID(mm) unit Part No. General Purpose Graphite Ferrules(short) 0.5 0.1, 0.2, 0.25, 0.32 10/pk 5080-8853 0.4 0.05-0.25 10/pk 500-2114 0.8 0.45, 0.53 10/pk 500-2118 1.0 0.53 10/pk 5080-8773 85% Vespel, 15% Graphite Ferrules(short) 0.4 0.1, 0.2, 0.25 10/pk 5181-3323 0.5 0.32 10/pk 5062-3514 0.8 0.45, 0.53 10/pk 5062-3512 Preconditioned 85% Vespel, 15% Graphite Ferrules(Long) 0.3 0.1 10/pk 5062-3507 0.4 0.1, 0.2, 0.25 10/pk 5062-3508 0.5 0.32 10/pk 5062-3506 0.8 0.53 10/pk 5062-3538 100% Vespel, High Performance Ferrules(Short) 0.4 0.1, 0.2, 0.25 10/pk 5181-3322 0.5 0.32 10/pk 5062-3513 0.8 0.45, 0.53 10/pk 5062-3511 Specialty Ferrules, 85% Vespel, 15% Graphite-Two Hole 0.4 0.1, 0.2, 0.25 10/pk 5062-3580 0.5 0.32 10/pk 5062-3581 No hole 10/pk 5181-3308 High Temp PTV Inlet, SS/Graphite 0.4 0.320 10/pk 5188-5315 0.4 0.530 10/pk 5188-5314 예일테크 2008.09.12
Ferrules
◈ Product Information
Using the wrong ferrule or a worn-out ferrule to seal your column connection can result in inconsistent and unreliable chromatography. An improper ferrule can cause leaks which allow air and other contaminants to enter the instrument through the column seal, causing major interference with column and detector performance. For optimum performance, ferrules should be replaced every time the column is replaced and when performing column maintenance.
► Graphite (100%) Ferrules
• General purpose for capillary columns
• Suitable for FID, NPD, and ECD
• Recommended for high temperature and cool on-column applications
• Material is free of sulfur and other contaminants
• Can be reused or removed easily
• Proper installation requires a finger-tight turn on the nut, then an additional 1/4 turn with a wrench
• Not for use with MS or oxygen sensitive detectors
► Vespel/Graphite (85%/15%) Ferrules
• General purpose for capillary columns
• Recommended for MS or oxygen sensitive detectors
• Also compatible with other detectors like FID and NPDs
• Most reliable leak free connection
• Proper installation requires a finger-tight turn on the nut, then an additional 1/4 turn with a wrench
• Ferrule hole MUST match the column OD exactly to ensure a leak-free seal
• Not reusable
► Vespel (100%) Ferrules
• Isothermal operation
• Can be reused or removed easily
• Excellent sealing material when making metal or glass connections
• Long lifetime
◈ Ordering Information Ferrule ID(mm) Column ID(mm) unit Part No. General Purpose Graphite Ferrules(short) 0.5 0.1, 0.2, 0.25, 0.32 10/pk 5080-8853 0.4 0.05-0.25 10/pk 500-2114 0.8 0.45, 0.53 10/pk 500-2118 1.0 0.53 10/pk 5080-8773 85% Vespel, 15% Graphite Ferrules(short) 0.4 0.1, 0.2, 0.25 10/pk 5181-3323 0.5 0.32 10/pk 5062-3514 0.8 0.45, 0.53 10/pk 5062-3512 Preconditioned 85% Vespel, 15% Graphite Ferrules(Long) 0.3 0.1 10/pk 5062-3507 0.4 0.1, 0.2, 0.25 10/pk 5062-3508 0.5 0.32 10/pk 5062-3506 0.8 0.53 10/pk 5062-3538 100% Vespel, High Performance Ferrules(Short) 0.4 0.1, 0.2, 0.25 10/pk 5181-3322 0.5 0.32 10/pk 5062-3513 0.8 0.45, 0.53 10/pk 5062-3511 Specialty Ferrules, 85% Vespel, 15% Graphite-Two Hole 0.4 0.1, 0.2, 0.25 10/pk 5062-3580 0.5 0.32 10/pk 5062-3581 No hole 10/pk 5181-3308 High Temp PTV Inlet, SS/Graphite 0.4 0.320 10/pk 5188-5315 0.4 0.530 10/pk 5188-5314 예일테크 2008.09.12
3
Agilent Liner O-Rings
Liner O-Rings
◈ Product Information
Liners are sealed in the inlet with O-rings or graphite seals. O-ring seals are easier to remove and to replace than graphite that deforms and flakes apart. The graphite seals should be used when inlet temperatures exceed 350°C.
► Point
• Pre-cleaned and conditioned to eliminate out-gassing of contaminants, especially important for trace, ECD and MSD analyses
• Plasma Treated for a Non-stick contaminant-free surface that won’t stick to the inlet metal surface creating un-necessary inlet maintenance
• Packaged for convenience and cleanliness—novel dial packaging for O-rings delivers 1 clean O-ring, ready for use
◈ Ordering Information Description unit Part No. Non-Stick Fluorocarbon O-ring 10/pk 5188-5365 Graphite O-ring for Splitless liner 10/pk 5180-4173 Graphite O-ring for Split liner 10/pk 5180-4168 Non-Stick Fluorocarbon Liner O-ring for Flip top 10/pk 5188-5366 High Temp PTV inlet Liner Fluorocarbon O-ring 10/pk 5188-5311 예일테크 2008.09.11
Liner O-Rings
◈ Product Information
Liners are sealed in the inlet with O-rings or graphite seals. O-ring seals are easier to remove and to replace than graphite that deforms and flakes apart. The graphite seals should be used when inlet temperatures exceed 350°C.
► Point
• Pre-cleaned and conditioned to eliminate out-gassing of contaminants, especially important for trace, ECD and MSD analyses
• Plasma Treated for a Non-stick contaminant-free surface that won’t stick to the inlet metal surface creating un-necessary inlet maintenance
• Packaged for convenience and cleanliness—novel dial packaging for O-rings delivers 1 clean O-ring, ready for use
◈ Ordering Information Description unit Part No. Non-Stick Fluorocarbon O-ring 10/pk 5188-5365 Graphite O-ring for Splitless liner 10/pk 5180-4173 Graphite O-ring for Split liner 10/pk 5180-4168 Non-Stick Fluorocarbon Liner O-ring for Flip top 10/pk 5188-5366 High Temp PTV inlet Liner Fluorocarbon O-ring 10/pk 5188-5311 예일테크 2008.09.11
2
Agilent Inlet Septa
Inlet Septa
◈ Product Information
One of the key components of sample introduction is the inlet septum. All columns must have sufficient carrier gas head pressure to establish flow through the column. Septa maintain the leak-free seal and exclude air from the inlet. They come in different sizes and are made from different types of materials specific to inlet type and analysis needs. Septa are available for a variety of different applications and have different upper temperature limits. Lower temperature septa are usually softer, seal better, and can withstand more punctures (injections) than their high-temperature counterparts. If septa are used above their recommended temperatures, however, they can leak or decompose. This causes sample losses, lower column flow, decreased column life and ghosting.
► Bleed and Temperature Optimized Non-Stick Septa(BTO)
• Extended temperature range, lowest bleed
• Maximum injection port temperature 400°C
• Plasma coating eliminates sticking in the injection port
• Pre-conditioned; ready to use
• Blister packaging for cleanliness and convenience
• Ideal for use with low-bleed, "Mass Spec" capillary columns
► Long-Life Non-Stick Septa
• The preferred septum for autosamplers
• Pre-pierced for extended life and reduced coring
• Ideal for overnight runs
• Up to 400 injections per septum
• Plasma coating eliminates sticking
• Maximum injection port temperature 350°C
• Soft, 45 Durometer, easy on autosampler needles
• Blister packaging for cleanliness and convenience
► Advanced Green Non-Stick Septa
• True long-life, high temperature green septum
• More injections per septum
• Plasma coating eliminates sticking in the injection port
• Maximum injection port temperature 350°C
• High-performance alternative to competitors' "Green" septa
• Blister packaging for cleanliness and convenience
◈ Ordering Information Description unit Part No. Bleed and Temperature Optimized Non-Stick Septa(BTO) 11mm septa 50/pk 5183-4757 11mm septa 100/pk 5183-4757-100 5mm septa through-hole for on-column, in glass jar 50/pk 5183-4758 Long-Life Non-Stick Septa 11mm septa 50/pk 5183-4761 11mm septa 100/pk 5183-4761-100 5mm septa through-hole for on-column, in glass jar 50/pk 5183-4762 Advanced Green Non-Stick Septa 11mm septa 50/pk 5183-4759 11mm septa 100/pk 5183-4759-100 5mm septa through-hole for on-column, in glass jar 50/pk 5183-4760 예일테크 2008.09.11
Inlet Septa
◈ Product Information
One of the key components of sample introduction is the inlet septum. All columns must have sufficient carrier gas head pressure to establish flow through the column. Septa maintain the leak-free seal and exclude air from the inlet. They come in different sizes and are made from different types of materials specific to inlet type and analysis needs. Septa are available for a variety of different applications and have different upper temperature limits. Lower temperature septa are usually softer, seal better, and can withstand more punctures (injections) than their high-temperature counterparts. If septa are used above their recommended temperatures, however, they can leak or decompose. This causes sample losses, lower column flow, decreased column life and ghosting.
► Bleed and Temperature Optimized Non-Stick Septa(BTO)
• Extended temperature range, lowest bleed
• Maximum injection port temperature 400°C
• Plasma coating eliminates sticking in the injection port
• Pre-conditioned; ready to use
• Blister packaging for cleanliness and convenience
• Ideal for use with low-bleed, "Mass Spec" capillary columns
► Long-Life Non-Stick Septa
• The preferred septum for autosamplers
• Pre-pierced for extended life and reduced coring
• Ideal for overnight runs
• Up to 400 injections per septum
• Plasma coating eliminates sticking
• Maximum injection port temperature 350°C
• Soft, 45 Durometer, easy on autosampler needles
• Blister packaging for cleanliness and convenience
► Advanced Green Non-Stick Septa
• True long-life, high temperature green septum
• More injections per septum
• Plasma coating eliminates sticking in the injection port
• Maximum injection port temperature 350°C
• High-performance alternative to competitors' "Green" septa
• Blister packaging for cleanliness and convenience
◈ Ordering Information Description unit Part No. Bleed and Temperature Optimized Non-Stick Septa(BTO) 11mm septa 50/pk 5183-4757 11mm septa 100/pk 5183-4757-100 5mm septa through-hole for on-column, in glass jar 50/pk 5183-4758 Long-Life Non-Stick Septa 11mm septa 50/pk 5183-4761 11mm septa 100/pk 5183-4761-100 5mm septa through-hole for on-column, in glass jar 50/pk 5183-4762 Advanced Green Non-Stick Septa 11mm septa 50/pk 5183-4759 11mm septa 100/pk 5183-4759-100 5mm septa through-hole for on-column, in glass jar 50/pk 5183-4760 예일테크 2008.09.11
1
Agilent Inlet Liners
Inlet Liners
◈ Product Information
Intensive liner development and testing have resulted in a set of liners that we recommend whenever new methods are being developed, when methods are being optimized, or when problems with existingmethods are encountered.
► Split Inlet Liners
glass wool, bottom taper, glass bead for easy positioning, deactivated
► Splitless Inlet Liners
single taperd liner without glass wool, deactivated
► Direct Inlet Liners
straight liner without glass wool, deactivated, for gas samples, headspace, or purge and trap applications only
◈ Ordering Information Description Volume (ul) ID (mm) unit Part No. Splitless Inlet Liners Single taper, deactivated 900 4 1/pk 5181-3316 5/pk 5183-4695 25/pk 5183-4696 Single taper, inert 900 4 1/pk 5181-3316i Single taper, glass wool, deactivated 900 4 1/pk 5062-3587 5/pk 5183-4693 25/pk 5183-4694 Double taper, deactivated 800 4 1/pk 5181-3315 5/pk 5183-4705 25/pk 5183-4706 Straight, deactivated, quartz 250 2 1/pk 5181-8818 5/pk 5183-4703 25/pk 5183-4704 Straight, non-deactivated, quartz 250 2 1/pk 18740-80220 5/pk 5183-4707 25/pk 5183-4708 Straight, non-deactivated 990 4 1/pk 210-3003 5/pk 210-3003-5 Split Inlet Liners Single taper, glass wool, deactivated (general purpose) 870 4 1/pk 5183-4711 5/pk 5183-4712 25/pk 5183-4713 Single taper, glass wool, deactivated, low pressure drop 870 4 1/pk 5183-4647 5/pk 5183-4701 25/pk 5183-4702 Straight, glass wool, non-deactivated 990 4 1/pk 19251-60540 5/pk 5183-4691 25/pk 5183-4692 Straight, with cup (for manual injections) 800 4 1/pk 18740-80190 5/pk 5183-4699 25/pk 5183-4700 Straight, with cup, glass wool and packing (for manual injections, not recommended for use with EPC) 800 4 1/pk 18740-60840 5/pk 5183-4697 25/pk 5183-4698 Direct Inlet Liners Straight, non-deactivated (for gas samples, headspace, or purge &trap) 140 1.5 1/pk 18740-80200 5/pk 5183-4709 25/pk 5183-4710
► Direct Connect Liners
• press fit connection to the column
• No sample exposure to the inlet
• Deactivated liners included in 8270 EPA application kit
• Inert Deactivated liner recommended for trace analysis of acids and bases
• Optimized hole size and placement
◈ Ordering Information Description Part No. Single Taper, Splitless, 4mm ID,
Deactivated G1544-80730 Dual Taper, Splitless, 4mm ID,
Deactivated G1544-80700 Single Taper, Splitless, 4mm ID,
Deactivated, Inert G1544-80731
► Focus Liners
• Improved reproducibility
• Precise amount of glass wool in the ideal position traps non-volatile sample residue
• Glass wool provides extra surface area for vaporization, traps nonvolatile sample residue, and wipes any residual sample from the needle
◈ Ordering Information Description unit Part No. Deactivated with glass wool,
4mm ID,
6.3mm x 78.5mm 5/pk 210-4004-5 Tapered,
deactivated with glass wool,
4mm ID
6.3mm x 78.5mm 5/pk 210-4022-5
► Programmable Temperature Vaporizing(PTV) Liners
◈ Ordering Information Description ID
(mm) Volume
(ul) Part No. PTV Liner,
Single Baffle,
Glass Wool,
Deactivated 2 180 5183-2038 PTV Liner,
Single Baffle,
Deactivated 2 200 5183-2036 PTV Liner,
Multi Baffled,
Deactivated 1.5 150 5183-2037 PTV Liner,
Fritted Glass,
Deactivated 1.5 150 5183-2041 PTV Liner,
high temperature,
quartz 3.4 713 5183-5313 PTV Liner,
high temperature,
borosilicate 3.4 668 5188-5356 예일테크 2008.09.10
Inlet Liners
◈ Product Information
Intensive liner development and testing have resulted in a set of liners that we recommend whenever new methods are being developed, when methods are being optimized, or when problems with existingmethods are encountered.
► Split Inlet Liners
glass wool, bottom taper, glass bead for easy positioning, deactivated
► Splitless Inlet Liners
single taperd liner without glass wool, deactivated
► Direct Inlet Liners
straight liner without glass wool, deactivated, for gas samples, headspace, or purge and trap applications only
◈ Ordering Information Description Volume (ul) ID (mm) unit Part No. Splitless Inlet Liners Single taper, deactivated 900 4 1/pk 5181-3316 5/pk 5183-4695 25/pk 5183-4696 Single taper, inert 900 4 1/pk 5181-3316i Single taper, glass wool, deactivated 900 4 1/pk 5062-3587 5/pk 5183-4693 25/pk 5183-4694 Double taper, deactivated 800 4 1/pk 5181-3315 5/pk 5183-4705 25/pk 5183-4706 Straight, deactivated, quartz 250 2 1/pk 5181-8818 5/pk 5183-4703 25/pk 5183-4704 Straight, non-deactivated, quartz 250 2 1/pk 18740-80220 5/pk 5183-4707 25/pk 5183-4708 Straight, non-deactivated 990 4 1/pk 210-3003 5/pk 210-3003-5 Split Inlet Liners Single taper, glass wool, deactivated (general purpose) 870 4 1/pk 5183-4711 5/pk 5183-4712 25/pk 5183-4713 Single taper, glass wool, deactivated, low pressure drop 870 4 1/pk 5183-4647 5/pk 5183-4701 25/pk 5183-4702 Straight, glass wool, non-deactivated 990 4 1/pk 19251-60540 5/pk 5183-4691 25/pk 5183-4692 Straight, with cup (for manual injections) 800 4 1/pk 18740-80190 5/pk 5183-4699 25/pk 5183-4700 Straight, with cup, glass wool and packing (for manual injections, not recommended for use with EPC) 800 4 1/pk 18740-60840 5/pk 5183-4697 25/pk 5183-4698 Direct Inlet Liners Straight, non-deactivated (for gas samples, headspace, or purge &trap) 140 1.5 1/pk 18740-80200 5/pk 5183-4709 25/pk 5183-4710
► Direct Connect Liners
• press fit connection to the column
• No sample exposure to the inlet
• Deactivated liners included in 8270 EPA application kit
• Inert Deactivated liner recommended for trace analysis of acids and bases
• Optimized hole size and placement
◈ Ordering Information Description Part No. Single Taper, Splitless, 4mm ID,
Deactivated G1544-80730 Dual Taper, Splitless, 4mm ID,
Deactivated G1544-80700 Single Taper, Splitless, 4mm ID,
Deactivated, Inert G1544-80731
► Focus Liners
• Improved reproducibility
• Precise amount of glass wool in the ideal position traps non-volatile sample residue
• Glass wool provides extra surface area for vaporization, traps nonvolatile sample residue, and wipes any residual sample from the needle
◈ Ordering Information Description unit Part No. Deactivated with glass wool,
4mm ID,
6.3mm x 78.5mm 5/pk 210-4004-5 Tapered,
deactivated with glass wool,
4mm ID
6.3mm x 78.5mm 5/pk 210-4022-5
► Programmable Temperature Vaporizing(PTV) Liners
◈ Ordering Information Description ID
(mm) Volume
(ul) Part No. PTV Liner,
Single Baffle,
Glass Wool,
Deactivated 2 180 5183-2038 PTV Liner,
Single Baffle,
Deactivated 2 200 5183-2036 PTV Liner,
Multi Baffled,
Deactivated 1.5 150 5183-2037 PTV Liner,
Fritted Glass,
Deactivated 1.5 150 5183-2041 PTV Liner,
high temperature,
quartz 3.4 713 5183-5313 PTV Liner,
high temperature,
borosilicate 3.4 668 5188-5356 예일테크 2008.09.10