GC
Inlet Liners
◈ Product Information
Intensive liner development and testing have resulted in a set of liners that we recommend whenever new methods are being developed, when methods are being optimized, or when problems with existingmethods are encountered.
► Split Inlet Liners
glass wool, bottom taper, glass bead for easy positioning, deactivated
► Splitless Inlet Liners
single taperd liner without glass wool, deactivated
► Direct Inlet Liners
straight liner without glass wool, deactivated, for gas samples, headspace, or purge and trap applications only
◈ Ordering Information
Description |
Volume (ul) |
ID (mm) |
unit |
Part No. | |
Splitless Inlet Liners | |||||
|
Single taper, deactivated |
900 |
4 |
1/pk |
5181-3316 |
5/pk |
5183-4695 | ||||
25/pk |
5183-4696 | ||||
Single taper, inert |
900 |
4 |
1/pk |
5181-3316i | |
|
Single taper, glass wool, deactivated |
900 |
4 |
1/pk |
5062-3587 |
5/pk |
5183-4693 | ||||
25/pk |
5183-4694 | ||||
|
Double taper, deactivated |
800 |
4 |
1/pk |
5181-3315 |
5/pk |
5183-4705 | ||||
25/pk |
5183-4706 | ||||
|
Straight, deactivated, quartz |
250 |
2 |
1/pk |
5181-8818 |
5/pk |
5183-4703 | ||||
25/pk |
5183-4704 | ||||
|
Straight, non-deactivated, quartz |
250 |
2 |
1/pk |
18740-80220 |
5/pk |
5183-4707 | ||||
25/pk |
5183-4708 | ||||
|
Straight, non-deactivated |
990 |
4 |
1/pk |
210-3003 |
5/pk |
210-3003-5 | ||||
Split Inlet Liners | |||||
|
Single taper, glass wool, deactivated (general purpose) |
870 |
4 |
1/pk |
5183-4711 |
5/pk |
5183-4712 | ||||
25/pk |
5183-4713 | ||||
|
Single taper, glass wool, deactivated, low pressure drop |
870 |
4 |
1/pk |
5183-4647 |
5/pk |
5183-4701 | ||||
25/pk |
5183-4702 | ||||
|
Straight, glass wool, non-deactivated |
990 |
4 |
1/pk |
19251-60540 |
5/pk |
5183-4691 | ||||
25/pk |
5183-4692 | ||||
|
Straight, with cup (for manual injections) |
800 |
4 |
1/pk |
18740-80190 |
5/pk |
5183-4699 | ||||
25/pk |
5183-4700 | ||||
|
Straight, with cup, glass wool and packing (for manual injections, not recommended for use with EPC) |
800 |
4 |
1/pk |
18740-60840 |
5/pk |
5183-4697 | ||||
25/pk |
5183-4698 | ||||
Direct Inlet Liners | |||||
|
Straight, non-deactivated (for gas samples, headspace, or purge &trap) |
140 |
1.5 |
1/pk |
18740-80200 |
5/pk |
5183-4709 | ||||
25/pk |
5183-4710 |
► Direct Connect Liners
• press fit connection to the column
• No sample exposure to the inlet
• Deactivated liners included in 8270 EPA application kit
• Inert Deactivated liner recommended for trace analysis of acids and bases
• Optimized hole size and placement
◈ Ordering Information
Description |
Part No. | |
Single Taper, Splitless, 4mm ID, |
G1544-80730 | |
Dual Taper, Splitless, 4mm ID, |
G1544-80700 | |
Single Taper, Splitless, 4mm ID, |
G1544-80731 |
► Focus Liners
• Improved reproducibility
• Precise amount of glass wool in the ideal position traps non-volatile sample residue
• Glass wool provides extra surface area for vaporization, traps nonvolatile sample residue, and wipes any residual sample from the needle
◈ Ordering Information
Description |
unit |
Part No. | |
Deactivated with glass wool, |
5/pk |
210-4004-5 | |
Tapered, |
5/pk |
210-4022-5 |
► Programmable Temperature Vaporizing(PTV) Liners
◈ Ordering Information
Description |
ID |
Volume |
Part No. | |
PTV Liner, |
2 |
180 |
5183-2038 | |
PTV Liner, |
2 |
200 |
5183-2036 | |
PTV Liner, |
1.5 |
150 |
5183-2037 | |
PTV Liner, |
1.5 |
150 |
5183-2041 | |
PTV Liner, |
3.4 |
713 |
5183-5313 | |
PTV Liner, |
3.4 |
668 |
5188-5356 |