Inlet Liners

◈ Product Information
Intensive liner development and testing have resulted in a set of liners that we recommend whenever new methods are being developed, when methods are being optimized, or when problems with existingmethods are encountered.

► Split Inlet Liners
glass wool, bottom taper, glass bead for easy positioning, deactivated

► Splitless Inlet Liners
single taperd liner without glass wool, deactivated

► Direct Inlet Liners
straight liner without glass wool, deactivated, for gas samples, headspace, or purge and trap applications only

◈ Ordering Information

Description

Volume (ul)

ID (mm)

unit

Part No.

Splitless Inlet Liners

 

 

Single taper, deactivated

900

4

1/pk

5181-3316

5/pk

5183-4695

25/pk

5183-4696

Single taper, inert

900

4

1/pk

5181-3316i

 

 

Single taper, glass wool, deactivated

900

4

1/pk

5062-3587

5/pk

5183-4693

25/pk

5183-4694

 

 

Double taper, deactivated

800

4

1/pk

5181-3315

5/pk

5183-4705

25/pk

5183-4706

Straight, deactivated, quartz

250

2

1/pk

5181-8818

5/pk

5183-4703

25/pk

5183-4704

Straight, non-deactivated, quartz

250

2

1/pk

18740-80220

5/pk

5183-4707

25/pk

5183-4708

Straight, non-deactivated

990

4

1/pk

210-3003

5/pk

210-3003-5

Split Inlet Liners

 

 

Single taper, glass wool, deactivated (general purpose)

870

4

1/pk

5183-4711

5/pk

5183-4712

25/pk

5183-4713

 

 

Single taper, glass wool, deactivated, low pressure drop

870

4

1/pk

5183-4647

5/pk

5183-4701

25/pk

5183-4702

Straight, glass wool, non-deactivated

990

4

1/pk

19251-60540

5/pk

5183-4691

25/pk

5183-4692

 

 

Straight, with cup (for manual injections)

800

4

1/pk

18740-80190

5/pk

5183-4699

25/pk

5183-4700

 

 

Straight, with cup, glass wool and packing (for manual injections, not recommended for use with EPC)

800

4

1/pk

18740-60840

5/pk

5183-4697

25/pk

5183-4698

Direct Inlet Liners

 

 

Straight, non-deactivated (for gas samples, headspace, or purge &trap)

140

1.5

1/pk

18740-80200

5/pk

5183-4709

25/pk

5183-4710



► Direct Connect Liners
 • press fit connection to the column
 • No sample exposure to the inlet
 • Deactivated liners included in 8270 EPA application kit
 • Inert Deactivated liner recommended for trace analysis of acids and bases
 • Optimized hole size and placement

◈ Ordering Information

Description

Part No.

Single Taper, Splitless, 4mm ID,
Deactivated

G1544-80730

Dual Taper, Splitless, 4mm ID,
Deactivated

G1544-80700

Single Taper, Splitless, 4mm ID,
Deactivated, Inert

G1544-80731



► Focus Liners
 • Improved reproducibility
 • Precise amount of glass wool in the ideal position traps non-volatile sample residue
 • Glass wool provides extra surface area for vaporization, traps nonvolatile sample residue, and wipes any residual sample from the needle

◈ Ordering Information

Description

unit

Part No.

Deactivated with glass wool,
4mm ID,
6.3mm x 78.5mm

5/pk

210-4004-5

Tapered,
deactivated with glass wool,
4mm ID
6.3mm x 78.5mm

5/pk

210-4022-5



► Programmable Temperature Vaporizing(PTV) Liners

◈ Ordering Information

Description

ID
(mm)

Volume
(ul)

Part No.

PTV Liner,
Single Baffle,
Glass Wool,
Deactivated

2

180

5183-2038

PTV Liner,
Single Baffle,
Deactivated

2

200

5183-2036

PTV Liner,
Multi Baffled,
Deactivated

1.5

150

5183-2037

PTV Liner,
Fritted Glass,
Deactivated

1.5

150

5183-2041

PTV Liner,
high temperature,
quartz

3.4

713

5183-5313

PTV Liner,
high temperature,
borosilicate

3.4

668

5188-5356