Thermo ScientificHypersil GOLD Column

◈ Product Information

Hypersil GOLD columns are based on improved, highly pure silica and a novel proprietary derivatization and endcapping procedure using alkyl chain chemistry.

Enhanced Resolution

Robust assay development requires a clear definition of resolution expectations. Narrow symmetrical chromatographic peaks ensure that optimum resolution is achieved. Obtaining narrow peak widths is especially challenging for basic pharmaceutical compounds. The reduced silanol activity on Hypersil GOLD columns reduces tailing for basic analytes, thus improving resolution.

Improved Sensitivity

Outstanding peak shape results in greater sensitivity. When peaks exhibit tailing, peak height is reduced, therefore compromising the sensitivity of the analysis. The highly symmetrical peaks provided by Hypersil GOLD columns enhance peak height and allow for optimised peak integration calculations. This can be particularly critical when low concentrations of an analyte are present, for example in an impurity assay.

Reproducibility

Our Hypersil GOLD columns are exceptionally reproducible for reliable chromatography, column after column. This allows the user to be confident that assays developed with Hypersil GOLD columns will be robust and stable for the life of the assay, making them an ideal choice for new method development.

pH Stability

Our Hypersil GOLD columns are well suited to extended pH applications and have been shown to produce robust assays at high pH. At low pH, excellent column stability and reproducibility are illustrated over 1500 injections at pH 1.8.

► Details

- Significant reduction in peak tailing while retaining C18 (USP L1) selectivity
- Excellent resolution, efficiency and sensitivity
- Confidence in the accuracy and quality of analytical data
- 1.9um particle size columns can be used to improve speed and efficiency


► Specifications

- Particle Size : 1.9, 3, 5, 8, 12µm
- pH [Range] : 1 to 11
- Pore Size : 175Angstroms
- Carbon Load : 10%
- Endcapped : Yes
- USP Type : L1


► Ordering Information

Hypersil GOLD Column
Particle
Size
Length
(mm)
4.6mm ID 4.0mm ID 3.0mm ID 2.1mm ID 1.0mm ID
1.9um 20 - - 25002-023030 25002-022130 25002-021030
30 - - 25002-033030 25002-032130 25002-031030
50 25002-054630 - 25002-053030 25002-052130 25002-051030
100 - - 25002-103030 25002-102130 25002-101030
150 - - - 25002-152130 -
200 - - - 25002-202130 -
3um 30 25003-034630 25003-034030 25003-033030 25003-032130 25003-031030
50 25003-054630 25003-054030 25003-053030 25003-052130 25003-051030
100 25003-104630 25003-104030 25003-103030 25003-102130 25003-101030
150 25003-154630 25003-154030 25003-153030 25003-152130 25003-151030
5um 30 25005-034630 25005-034030 25005-033030 25005-032130 25005-031030
50 25005-054630 25005-054030 25005-053030 25005-052130 25005-051030
100 25005-104630 25005-104030 25005-103030 25005-102130 25005-101030
150 25005-154630 25005-154030 25005-153030 25005-152130 25005-151030
250 25005-254630 25005-254030 25005-253030 25005-252130 25005-251030
8um 150 25008-154630 - - - -
250 25008-254630 - - - -
Hypersil GOLD Drop-in Guard Cartridges(pk/4)
Particle
Size
Length
(mm)
4.0mm ID 4.6mm ID 3.0mm ID 2.0mm ID 1.0mm ID
3um 10 25003-014001 25003-014001 25003-013001 25003-012101 25003-011001
5um 10 25005-014001 25005-014001 25005-013001 25005-012101 25005-011001
UNIGUARD
Direct-Connect
Drop-in Guard
Cartridge Holder
(ea/1)