Agilent
38
Agilent HP-20M
HP-20M
◈ Product Information
Agilent J&W Scientific GC columns are designed and manufactured to offer excellent and reproducible performance for the benign to the most difficult types of samples. With the lowest bleed levels, the best inertness for acids/bases/mixed functional compounds,and the tight est column-to-column reproducibility - Agilent GC columns are of higher quality and perform better than any other columns on the market.
► Point
• Polyethylene glycol, MW 20,000
• Equivalent to USP Phase G16
► Similar Phases
- DB-WAX, HP-INNOWax, DB-WAXeter
◈ Ordering Information ID(mm) Length(m) Film(um) Temp Limits(°C) Part No. 0.20 25 0.10 60 to 220 19091W-102 0.20 50 0.10 60 to 220 19091W-105 0.32 25 0.30 60 to 220 19091W-012 0.32 50 0.30 60 to 220 19091W-015 0.53 10 1.33 60 to 220 19095W-121 0.53 30 1.33 60 to 220 19095W-123 예일테크 2008.06.23
HP-20M
◈ Product Information
Agilent J&W Scientific GC columns are designed and manufactured to offer excellent and reproducible performance for the benign to the most difficult types of samples. With the lowest bleed levels, the best inertness for acids/bases/mixed functional compounds,and the tight est column-to-column reproducibility - Agilent GC columns are of higher quality and perform better than any other columns on the market.
► Point
• Polyethylene glycol, MW 20,000
• Equivalent to USP Phase G16
► Similar Phases
- DB-WAX, HP-INNOWax, DB-WAXeter
◈ Ordering Information ID(mm) Length(m) Film(um) Temp Limits(°C) Part No. 0.20 25 0.10 60 to 220 19091W-102 0.20 50 0.10 60 to 220 19091W-105 0.32 25 0.30 60 to 220 19091W-012 0.32 50 0.30 60 to 220 19091W-015 0.53 10 1.33 60 to 220 19095W-121 0.53 30 1.33 60 to 220 19095W-123 예일테크 2008.06.23
37
Agilent Carbowax 20M
Carbowax 20M
◈ Product Information
Agilent J&W Scientific GC columns are designed and manufactured to offer excellent and reproducible performance for the benign to the most difficult types of samples. With the lowest bleed levels, the best inertness for acids/bases/mixed functional compounds,and the tight est column-to-column reproducibility - Agilent GC columns are of higher quality and perform better than any other columns on the market.
► Point
• Polyethylene glycol, MW 20,000
• Equivalent to USP Phase G16
► Similar Phases
- DB-WAX, HP-INNOWax, DB-WAXeter
◈ Ordering Information ID(mm) Length(m) Film(um) Temp Limits(°C) Part No. 0.25 30 0.25 60 to 220/240 112-2032 0.32 30 0.25 60 to 220/240 113-2032 예일테크 2008.06.23
Carbowax 20M
◈ Product Information
Agilent J&W Scientific GC columns are designed and manufactured to offer excellent and reproducible performance for the benign to the most difficult types of samples. With the lowest bleed levels, the best inertness for acids/bases/mixed functional compounds,and the tight est column-to-column reproducibility - Agilent GC columns are of higher quality and perform better than any other columns on the market.
► Point
• Polyethylene glycol, MW 20,000
• Equivalent to USP Phase G16
► Similar Phases
- DB-WAX, HP-INNOWax, DB-WAXeter
◈ Ordering Information ID(mm) Length(m) Film(um) Temp Limits(°C) Part No. 0.25 30 0.25 60 to 220/240 112-2032 0.32 30 0.25 60 to 220/240 113-2032 예일테크 2008.06.23
36
Agilent HP-PLOT Q
HP-PLOT Q
◈ Product Information
The HP-PLOT Q is a bonded polystyrene-divinylbenzene (DVB) based column that has been specially developed for the separation of targeted apolar and polar compounds including: Hydrocarbon (natural gas, refinery gas, ethylene, propylene, all C1-C3 isomers); CO2, methane, air/CO, and water; Polar solvents (methanol, acetone, methylene chloride, alcohols, ketones, aldehydes, esters); and Sulfur compounds (H2S, mercaptans, COS).
► Point
• Resolves 2,3,7,8-TCDD and 2,3,7,8-TCDF from all other isomers in one run
• Low bleed
• Bonded and cross-linked
• Solvent rinsable
► Similar Phases
- CP PoraPLOT Q, CP PoraPLOT Q-HT, Rt-QPLOT, SupelQ PLOT, GS-Q
◈ Ordering Information ID(mm) Length(m) Film(um) Temp Limits(°C) Part No. 0.32 15 20.00 -60 to 270/290 19091P-Q03 0.32 30 20.00 -60 to 270/290 19091P-Q04 0.53 15 40.00 -60 to 270/290 19095P-Q03 0.53 30 40.00 -60 to 270/290 19095P-Q04 예일테크 2008.06.20
HP-PLOT Q
◈ Product Information
The HP-PLOT Q is a bonded polystyrene-divinylbenzene (DVB) based column that has been specially developed for the separation of targeted apolar and polar compounds including: Hydrocarbon (natural gas, refinery gas, ethylene, propylene, all C1-C3 isomers); CO2, methane, air/CO, and water; Polar solvents (methanol, acetone, methylene chloride, alcohols, ketones, aldehydes, esters); and Sulfur compounds (H2S, mercaptans, COS).
► Point
• Resolves 2,3,7,8-TCDD and 2,3,7,8-TCDF from all other isomers in one run
• Low bleed
• Bonded and cross-linked
• Solvent rinsable
► Similar Phases
- CP PoraPLOT Q, CP PoraPLOT Q-HT, Rt-QPLOT, SupelQ PLOT, GS-Q
◈ Ordering Information ID(mm) Length(m) Film(um) Temp Limits(°C) Part No. 0.32 15 20.00 -60 to 270/290 19091P-Q03 0.32 30 20.00 -60 to 270/290 19091P-Q04 0.53 15 40.00 -60 to 270/290 19095P-Q03 0.53 30 40.00 -60 to 270/290 19095P-Q04 예일테크 2008.06.20
35
Agilent DB-Dioxin
DB-Dioxin
◈ Product Information
Agilent J&W DB-Dioxin columns are specifically engineered for the analysis of Polychlorinated Dibenzodioxins (PCDD) and Dibenzofurans (PCDF). Note: 100 psi regulator required to reach optimum carrier gas velocity
► Point
• Resolves 2,3,7,8-TCDD and 2,3,7,8-TCDF from all other isomers in one run
• Low bleed
• Bonded and cross-linked
• Solvent rinsable
► Similar Phases
- SP-2331, 007-23, Rtx-2332, CP Sil 88
◈ Ordering Information ID(mm) Length(m) Film(um) Temp Limits(°C) Part No. 0.25 60 0.15 40 to 250/270 122-2461 0.25 60 0.25 40 to 250/270 122-2462 예일테크 2008.06.20
DB-Dioxin
◈ Product Information
Agilent J&W DB-Dioxin columns are specifically engineered for the analysis of Polychlorinated Dibenzodioxins (PCDD) and Dibenzofurans (PCDF). Note: 100 psi regulator required to reach optimum carrier gas velocity
► Point
• Resolves 2,3,7,8-TCDD and 2,3,7,8-TCDF from all other isomers in one run
• Low bleed
• Bonded and cross-linked
• Solvent rinsable
► Similar Phases
- SP-2331, 007-23, Rtx-2332, CP Sil 88
◈ Ordering Information ID(mm) Length(m) Film(um) Temp Limits(°C) Part No. 0.25 60 0.15 40 to 250/270 122-2461 0.25 60 0.25 40 to 250/270 122-2462 예일테크 2008.06.20
34
Agilent HP-Chiral ß
HP-Chiral ß
◈ Product Information
This capillary column is a chiral stationary phase column based on permethylated beta-cyclodextran which has very broad applications for resolving volatile optical isomers. In the HP-Chiral ß column, the beta-cyclodextrin is dispersed in phenyl-based polymer. This polymer provides low bleed and will not interfere with nitrogen-specific detectors like the nitrogen phosphorus (NPD) detector, allowing optimized sensitivity for chiral compounds containing nitrogen.
► Point
• Beta-cyclodextrin in (35%-Phenyl)-methylpolysiloxane
• Chiral separations without chiral specific derivatization
• Phenyl-based polymer provides low bleed and does not interfere with nitrogen-specific detectors
• Available in two concentrations of beta-cyclodextrin: 10% and 20%
• 20% beta-cyclodextrin best choice for initial screening
► Similar Phases
- LIPODEX C, Rt-ßDEXm, ß-DEX 110/120
◈ Ordering Information ID(mm) Length(m) Film(um) Temp Limits(°C) Part No. HP-Chiral 10β 0.25 30 0.25 30 to 240/250 19091G-B133 HP-Chiral 20β 0.25 30 0.25 30 to 240/250 19091G-B233 0.32 30 0.25 30 to 240/250 19091G-B213 예일테크 2008.06.20
HP-Chiral ß
◈ Product Information
This capillary column is a chiral stationary phase column based on permethylated beta-cyclodextran which has very broad applications for resolving volatile optical isomers. In the HP-Chiral ß column, the beta-cyclodextrin is dispersed in phenyl-based polymer. This polymer provides low bleed and will not interfere with nitrogen-specific detectors like the nitrogen phosphorus (NPD) detector, allowing optimized sensitivity for chiral compounds containing nitrogen.
► Point
• Beta-cyclodextrin in (35%-Phenyl)-methylpolysiloxane
• Chiral separations without chiral specific derivatization
• Phenyl-based polymer provides low bleed and does not interfere with nitrogen-specific detectors
• Available in two concentrations of beta-cyclodextrin: 10% and 20%
• 20% beta-cyclodextrin best choice for initial screening
► Similar Phases
- LIPODEX C, Rt-ßDEXm, ß-DEX 110/120
◈ Ordering Information ID(mm) Length(m) Film(um) Temp Limits(°C) Part No. HP-Chiral 10β 0.25 30 0.25 30 to 240/250 19091G-B133 HP-Chiral 20β 0.25 30 0.25 30 to 240/250 19091G-B233 0.32 30 0.25 30 to 240/250 19091G-B213 예일테크 2008.06.20
33
Agilent Cyclodex-B
Cyclodex-B
◈ Product Information
Agilent makes more capillary columns than anyone else in the world and our commitment to product reliability and repeatability has raised the level of quality that chromatographers demand. We continue to tighten our performance criteria such as separation efficiency, retention characteristics, peak height ratios, and bleed rates.
► Point
• 10.5% Beta-Cyclodextrin in DB-1701
• Chiral separations without chiral specific derivatization
• Broad range of resolving potential
• Excellent peak shape
► Similar Phases
- LIPODEX C, Rt-ß DEXm, ß-DEX 110, ß-DEX 120
◈ Ordering Information ID(mm) Length(m) Film(um) Temp Limits(°C) Part No. 0.25 30 0.25 50 to 230/250 112-2532 0.25 60 0.25 50 to 230/250 112-2562 0.32 30 0.25 50 to 230/250 113-2532 예일테크 2008.06.20
Cyclodex-B
◈ Product Information
Agilent makes more capillary columns than anyone else in the world and our commitment to product reliability and repeatability has raised the level of quality that chromatographers demand. We continue to tighten our performance criteria such as separation efficiency, retention characteristics, peak height ratios, and bleed rates.
► Point
• 10.5% Beta-Cyclodextrin in DB-1701
• Chiral separations without chiral specific derivatization
• Broad range of resolving potential
• Excellent peak shape
► Similar Phases
- LIPODEX C, Rt-ß DEXm, ß-DEX 110, ß-DEX 120
◈ Ordering Information ID(mm) Length(m) Film(um) Temp Limits(°C) Part No. 0.25 30 0.25 50 to 230/250 112-2532 0.25 60 0.25 50 to 230/250 112-2562 0.32 30 0.25 50 to 230/250 113-2532 예일테크 2008.06.20
32
Agilent CycloSil-B
CycloSil-B
◈ Product Information
Agilent makes more capillary columns than anyone else in the world and our commitment to product reliability and repeatability has raised the level of quality that chromatographers demand. We continue to tighten our performance criteria such as separation efficiency, retention characteristics, peak height ratios, and bleed rates. Note: Because CycloSil-B GC columns are not bonded or cross-linked, Agilent does not recommend solvent rinsing.
► Point
• 30% hepatkis (2,3-di-O-methyl-6-O-t-butyl dimethylsilyl)-ß-cyclodextrin in DB-1701
• Chiral separations without chiral specific derivatization
• New stationary phase for improved resolution of many chiral separations
• Ideal for many chiral ý-lactones and terpenes
► Similar Phases
- LIPODEX C, Rt-ß DEXm, ß-DEX 110, ß-DEX 120
◈ Ordering Information ID(mm) Length(m) Film(um) Temp Limits(°C) Part No. 0.25 30 0.25 35 to 260/280 112-6632 0.32 30 0.25 35 to 260/280 113-6632 예일테크 2008.06.20
CycloSil-B
◈ Product Information
Agilent makes more capillary columns than anyone else in the world and our commitment to product reliability and repeatability has raised the level of quality that chromatographers demand. We continue to tighten our performance criteria such as separation efficiency, retention characteristics, peak height ratios, and bleed rates. Note: Because CycloSil-B GC columns are not bonded or cross-linked, Agilent does not recommend solvent rinsing.
► Point
• 30% hepatkis (2,3-di-O-methyl-6-O-t-butyl dimethylsilyl)-ß-cyclodextrin in DB-1701
• Chiral separations without chiral specific derivatization
• New stationary phase for improved resolution of many chiral separations
• Ideal for many chiral ý-lactones and terpenes
► Similar Phases
- LIPODEX C, Rt-ß DEXm, ß-DEX 110, ß-DEX 120
◈ Ordering Information ID(mm) Length(m) Film(um) Temp Limits(°C) Part No. 0.25 30 0.25 35 to 260/280 112-6632 0.32 30 0.25 35 to 260/280 113-6632 예일테크 2008.06.20
31
Agilent HP-FFAP
HP-FFAP
◈ Product Information
The HP-FFAP columns are designed primarily for the analysis of organic acids, free fatty acids, or samples that require quantitation of acidic impurities. The stationary phase is modified with acid to provide a very inert column that can accomodate the demanding analysis of acids dissolved in water. Free fatty acids up to C24 can be analyzed without costly and time consuming derivatization. The HP-FFAP does not require priming (several injections of acids) so accurate results can be obtained quickly.
► Point
• Nitroterephthalic acid modified polyethylene glycol
• High polarity
• Designed for the analysis of volatile fatty acids and phenols
• Replaces OV-351
• Bonded and cross-linked; solvent rinsable
• Close equivalent to USP Phase G35
• Can be used at operating temperatures at 60-250ºC
► Similar Phases
- Stabilwax-DA, DB-FFAP, Nukol, 007-FFAP, BP21, CP-Wax 58 (FFAP) CB, AT-1000, OV-351, CP-FFAP-CB
◈ Ordering Information ID(mm) Length(m) Film(um) Temp Limits(°C) Part No. 0.20 25 0.30 60 to 240/250 19091F-102 0.20 50 0.30 60 to 240/250 19091F-105 0.25 30 0.25 60 to 240/250 19091F-433 0.32 25 0.50 60 to 240/250 19091F-112 0.32 30 0.25 60 to 240/250 19091F-413 0.32 50 0.50 60 to 240/250 19091F-115 0.53 10 1.00 60 to 240 19095F-121 0.53 15 1.00 60 to 240 19095F-120 0.53 30 1.00 60 to 240 19095F-123 예일테크 2008.06.20
HP-FFAP
◈ Product Information
The HP-FFAP columns are designed primarily for the analysis of organic acids, free fatty acids, or samples that require quantitation of acidic impurities. The stationary phase is modified with acid to provide a very inert column that can accomodate the demanding analysis of acids dissolved in water. Free fatty acids up to C24 can be analyzed without costly and time consuming derivatization. The HP-FFAP does not require priming (several injections of acids) so accurate results can be obtained quickly.
► Point
• Nitroterephthalic acid modified polyethylene glycol
• High polarity
• Designed for the analysis of volatile fatty acids and phenols
• Replaces OV-351
• Bonded and cross-linked; solvent rinsable
• Close equivalent to USP Phase G35
• Can be used at operating temperatures at 60-250ºC
► Similar Phases
- Stabilwax-DA, DB-FFAP, Nukol, 007-FFAP, BP21, CP-Wax 58 (FFAP) CB, AT-1000, OV-351, CP-FFAP-CB
◈ Ordering Information ID(mm) Length(m) Film(um) Temp Limits(°C) Part No. 0.20 25 0.30 60 to 240/250 19091F-102 0.20 50 0.30 60 to 240/250 19091F-105 0.25 30 0.25 60 to 240/250 19091F-433 0.32 25 0.50 60 to 240/250 19091F-112 0.32 30 0.25 60 to 240/250 19091F-413 0.32 50 0.50 60 to 240/250 19091F-115 0.53 10 1.00 60 to 240 19095F-121 0.53 15 1.00 60 to 240 19095F-120 0.53 30 1.00 60 to 240 19095F-123 예일테크 2008.06.20
30
Agilent DB-FFAP
DB-FFAP
◈ Product Information
Agilent offers two series of molecular sieve PLOT columns in 0.53- and 0.32-mm i.d. dimensions. For applications requiring resolution of argon and oxygen without expensive cryogenic cooling, select thick-film HP-PLOT MoleSieve/5A columns. The economical thin-film columns are ideal for many applications, including routine air monitoring and analysis in less than 10 seconds. The thin-film column resolves argon and oxygen at subambient temperatures.
► Point
• Polyethylene glycol (PEG)
• High polarity
• Highest upper temperature limits of bonded PEG phases
• Column-to-column repeatability
• Bonded and cross-linked
• Solvent rinsable
• Close equivalent to USP Phase G16
► Similar Phases
- Stabilwax-DA, HP-FFAP, Nukol, 007-FFAP, BP21, CP-Wax 58 (FFAP) CB, AT-1000, OV-351, CP-FFAP-CB
◈ Ordering Information ID(mm) Length(m) Film(um) Temp Limits(°C) Part No. 0.25 15 0.25 40 to 250 122-3212 0.25 30 0.25 40 to 250 122-3232 0.25 30 0.50 40 to 250 122-3233 0.25 60 0.25 40 to 250 122-3262 0.25 60 0.50 40 to 250 122-3263 0.32 15 0.25 40 to 250 123-3212 0.32 25 0.50 40 to 250 123-3223 0.32 30 0.25 40 to 250 123-3232 0.32 30 0.50 40 to 250 123-3233 0.32 30 1.00 40 to 250 123-3234 0.32 50 0.50 40 to 250 123-3253 0.32 60 0.25 40 to 250 123-3262 0.32 60 0.50 40 to 250 123-3263 0.32 60 1.00 40 to 250 123-3264 0.45 30 0.85 40 to 250 124-3232 0.53 10 1.00 40 to 250 125-32H2 0.53 15 0.50 40 to 250 125-3217 0.53 15 1.00 40 to 250 125-3212 0.53 30 0.25 40 to 250 125-3231 0.53 30 0.50 40 to 250 125-3237 0.53 30 1.00 40 to 250 125-3232 0.53 30 1.50 40 to 250 125-3233 0.53 60 1.00 40 to 250 125-3262 예일테크 2008.06.20
DB-FFAP
◈ Product Information
Agilent offers two series of molecular sieve PLOT columns in 0.53- and 0.32-mm i.d. dimensions. For applications requiring resolution of argon and oxygen without expensive cryogenic cooling, select thick-film HP-PLOT MoleSieve/5A columns. The economical thin-film columns are ideal for many applications, including routine air monitoring and analysis in less than 10 seconds. The thin-film column resolves argon and oxygen at subambient temperatures.
► Point
• Polyethylene glycol (PEG)
• High polarity
• Highest upper temperature limits of bonded PEG phases
• Column-to-column repeatability
• Bonded and cross-linked
• Solvent rinsable
• Close equivalent to USP Phase G16
► Similar Phases
- Stabilwax-DA, HP-FFAP, Nukol, 007-FFAP, BP21, CP-Wax 58 (FFAP) CB, AT-1000, OV-351, CP-FFAP-CB
◈ Ordering Information ID(mm) Length(m) Film(um) Temp Limits(°C) Part No. 0.25 15 0.25 40 to 250 122-3212 0.25 30 0.25 40 to 250 122-3232 0.25 30 0.50 40 to 250 122-3233 0.25 60 0.25 40 to 250 122-3262 0.25 60 0.50 40 to 250 122-3263 0.32 15 0.25 40 to 250 123-3212 0.32 25 0.50 40 to 250 123-3223 0.32 30 0.25 40 to 250 123-3232 0.32 30 0.50 40 to 250 123-3233 0.32 30 1.00 40 to 250 123-3234 0.32 50 0.50 40 to 250 123-3253 0.32 60 0.25 40 to 250 123-3262 0.32 60 0.50 40 to 250 123-3263 0.32 60 1.00 40 to 250 123-3264 0.45 30 0.85 40 to 250 124-3232 0.53 10 1.00 40 to 250 125-32H2 0.53 15 0.50 40 to 250 125-3217 0.53 15 1.00 40 to 250 125-3212 0.53 30 0.25 40 to 250 125-3231 0.53 30 0.50 40 to 250 125-3237 0.53 30 1.00 40 to 250 125-3232 0.53 30 1.50 40 to 250 125-3233 0.53 60 1.00 40 to 250 125-3262 예일테크 2008.06.20
29
Agilent DB-INNOWax
DB-INNOWax
◈ Product Information
Agilent makes more capillary columns than anyone else in the world and our commitment to product reliability and repeatability has raised the level of quality that chromatographers demand. We continue to tighten our performance criteria such as separation efficiency, retention characteristics, peak height ratios, and bleed rates.
► Point
• Polyethylene glycol (PEG)
• High polarity
• Highest upper temperature limits of bonded PEG phases
• Column-to-column repeatability
• Bonded and cross-linked
• Solvent rinsable
• Close equivalent to USP Phase G16
► Similar Phases
- HP-20M, SUPELCOWAX 10, CP-WAX 52CB, SUPEROX II, CB-WAX, STABILWAX, BP-20, 007-CW, Carbowax, HP-WAXetr, ZB-WAX
◈ Ordering Information ID(mm) Length(m) Film(um) Temp Limits(°C) Part No. 0.20 25 0.20 40 to 260/270 19091N-102 0.20 25 0.40 40 to 260/270 19091N-202 0.20 50 0.20 40 to 260/270 19091N-105 0.20 50 0.40 40 to 260/270 19091N-205 0.25 15 0.25 40 to 260/270 19091N-131 0.25 15 0.50 40 to 260/270 19091N-231 0.25 30 0.15 40 to 260/270 19091N-033 0.25 30 0.25 40 to 260/270 19091N-133 0.25 30 0.50 40 to 260/270 19091N-233 0.25 60 0.15 40 to 260/270 19091N-036 0.25 60 0.25 40 to 260/270 19091N-136 0.25 60 0.50 40 to 260/270 19091N-236 0.32 15 0.25 40 to 260/270 19091N-111 0.32 30 0.15 40 to 260/270 19091N-013 0.32 30 0.25 40 to 260/270 19091N-113 0.32 30 0.50 40 to 260/270 19091N-213 0.32 60 0.25 40 to 260/270 19091N-116 0.32 60 0.50 40 to 260/270 19091N-216 0.53 15 1.00 40 to 240/250 19095N-121 0.53 30 1.00 40 to 240/250 19095N-123 0.53 60 1.00 40 to 240/250 19095N-126 예일테크 2008.06.20
DB-INNOWax
◈ Product Information
Agilent makes more capillary columns than anyone else in the world and our commitment to product reliability and repeatability has raised the level of quality that chromatographers demand. We continue to tighten our performance criteria such as separation efficiency, retention characteristics, peak height ratios, and bleed rates.
► Point
• Polyethylene glycol (PEG)
• High polarity
• Highest upper temperature limits of bonded PEG phases
• Column-to-column repeatability
• Bonded and cross-linked
• Solvent rinsable
• Close equivalent to USP Phase G16
► Similar Phases
- HP-20M, SUPELCOWAX 10, CP-WAX 52CB, SUPEROX II, CB-WAX, STABILWAX, BP-20, 007-CW, Carbowax, HP-WAXetr, ZB-WAX
◈ Ordering Information ID(mm) Length(m) Film(um) Temp Limits(°C) Part No. 0.20 25 0.20 40 to 260/270 19091N-102 0.20 25 0.40 40 to 260/270 19091N-202 0.20 50 0.20 40 to 260/270 19091N-105 0.20 50 0.40 40 to 260/270 19091N-205 0.25 15 0.25 40 to 260/270 19091N-131 0.25 15 0.50 40 to 260/270 19091N-231 0.25 30 0.15 40 to 260/270 19091N-033 0.25 30 0.25 40 to 260/270 19091N-133 0.25 30 0.50 40 to 260/270 19091N-233 0.25 60 0.15 40 to 260/270 19091N-036 0.25 60 0.25 40 to 260/270 19091N-136 0.25 60 0.50 40 to 260/270 19091N-236 0.32 15 0.25 40 to 260/270 19091N-111 0.32 30 0.15 40 to 260/270 19091N-013 0.32 30 0.25 40 to 260/270 19091N-113 0.32 30 0.50 40 to 260/270 19091N-213 0.32 60 0.25 40 to 260/270 19091N-116 0.32 60 0.50 40 to 260/270 19091N-216 0.53 15 1.00 40 to 240/250 19095N-121 0.53 30 1.00 40 to 240/250 19095N-123 0.53 60 1.00 40 to 240/250 19095N-126 예일테크 2008.06.20
28
Agilent DB-WAXetr
DB-WAXetr
◈ Product Information
Agilent makes more capillary columns than anyone else in the world and our commitment to product reliability and repeatability has raised the level of quality that chromatographers demand. We continue to tighten our performance criteria such as separation efficiency, retention characteristics, peak height ratios, and bleed rates.
► Point
• Polyethylene glycol (PEG)
• High polarity
• Extended temperature range (etr)
• Excellent column-to-column repeatability
• Bonded and cross-linked
• Solvent rinsable
• Close equivalent to USP Phase G16
► Similar Phases
- HP-20M, SUPELCOWAX 10, CP-WAX 52CB, SUPEROX II, CB-WAX, STABILWAX, BP-20, 007-CW, Carbowax, HP-Innowax, ZB-WAX
◈ Ordering Information ID(mm) Length(m) Film(um) Temp Limits(°C) Part No. 0.20 25 0.40 30 to 250/260 128-7323 0.25 30 0.25 30 to 260/280 122-7332 0.25 30 0.50 30 to 250/260 122-7333 0.25 60 0.25 30 to 260/280 122-7362 0.25 60 0.50 30 to 250/260 122-7363 0.32 15 0.25 30 to 260/280 123-7312 0.32 15 1.00 30 to 250/260 123-7314 0.32 30 0.25 30 to 260/280 123-7332 0.32 30 0.50 30 to 250/260 123-7333 0.32 30 1.00 30 to 250/260 123-7334 0.32 50 1.00 30 to 250/260 123-7354 0.32 60 0.25 30 to 260/280 123-7362 0.32 60 0.50 30 to 250/260 123-7363 0.32 60 1.00 30 to 250/260 123-7364 0.53 15 1.00 30 to 240/260 125-7312 0.53 15 2.00 50 to 230/250 125-7314 0.53 30 1.00 30 to 240/260 125-7332 0.53 30 1.50 30 to 230/240 125-7333 0.53 30 2.00 50 to 230/250 125-7334 0.53 60 1.00 30 to 240/260 125-7362 예일테크 2008.06.20
DB-WAXetr
◈ Product Information
Agilent makes more capillary columns than anyone else in the world and our commitment to product reliability and repeatability has raised the level of quality that chromatographers demand. We continue to tighten our performance criteria such as separation efficiency, retention characteristics, peak height ratios, and bleed rates.
► Point
• Polyethylene glycol (PEG)
• High polarity
• Extended temperature range (etr)
• Excellent column-to-column repeatability
• Bonded and cross-linked
• Solvent rinsable
• Close equivalent to USP Phase G16
► Similar Phases
- HP-20M, SUPELCOWAX 10, CP-WAX 52CB, SUPEROX II, CB-WAX, STABILWAX, BP-20, 007-CW, Carbowax, HP-Innowax, ZB-WAX
◈ Ordering Information ID(mm) Length(m) Film(um) Temp Limits(°C) Part No. 0.20 25 0.40 30 to 250/260 128-7323 0.25 30 0.25 30 to 260/280 122-7332 0.25 30 0.50 30 to 250/260 122-7333 0.25 60 0.25 30 to 260/280 122-7362 0.25 60 0.50 30 to 250/260 122-7363 0.32 15 0.25 30 to 260/280 123-7312 0.32 15 1.00 30 to 250/260 123-7314 0.32 30 0.25 30 to 260/280 123-7332 0.32 30 0.50 30 to 250/260 123-7333 0.32 30 1.00 30 to 250/260 123-7334 0.32 50 1.00 30 to 250/260 123-7354 0.32 60 0.25 30 to 260/280 123-7362 0.32 60 0.50 30 to 250/260 123-7363 0.32 60 1.00 30 to 250/260 123-7364 0.53 15 1.00 30 to 240/260 125-7312 0.53 15 2.00 50 to 230/250 125-7314 0.53 30 1.00 30 to 240/260 125-7332 0.53 30 1.50 30 to 230/240 125-7333 0.53 30 2.00 50 to 230/250 125-7334 0.53 60 1.00 30 to 240/260 125-7362 예일테크 2008.06.20
27
Agilent DB-WaxFF
DB-WaxFF
◈ Product Information
The DB-WaxFF is a highly reproducible microbore version of our regular DB-Wax column that has also been specially tested to insure maximum column to column reproducibility. It is an excellent column for separation of complex fragrances.
► Point
• Polyethylene glycol (PEG)
• Close equivalent to USP Phase G16
• High polarity
• Lower temperature limit of 20°C is lowest of any bonded PEG phase; improves resolution of low boiling point analytes
• Column-to-column repeatability is unmatched by other microbore columns
• Bonded and cross-linked
• Solvent rinsable
• Exact replacement of HP-WAX
► Similar Phases
- HP-20M, SUPELCOWAX 10, CP-WAX 52CB, SUPEROX II, CB-WAX, Stabilwax, BP-20, 007-CW, Carbowax, HP-Innowax, Rtx-WAX, ZB-WAX
◈ Ordering Information ID(mm) Length(m) Film(um) Temp Limits(°C) Part No. 0.10 20 0.20 20 to 240/250 127-7023FF 예일테크 2008.06.20
DB-WaxFF
◈ Product Information
The DB-WaxFF is a highly reproducible microbore version of our regular DB-Wax column that has also been specially tested to insure maximum column to column reproducibility. It is an excellent column for separation of complex fragrances.
► Point
• Polyethylene glycol (PEG)
• Close equivalent to USP Phase G16
• High polarity
• Lower temperature limit of 20°C is lowest of any bonded PEG phase; improves resolution of low boiling point analytes
• Column-to-column repeatability is unmatched by other microbore columns
• Bonded and cross-linked
• Solvent rinsable
• Exact replacement of HP-WAX
► Similar Phases
- HP-20M, SUPELCOWAX 10, CP-WAX 52CB, SUPEROX II, CB-WAX, Stabilwax, BP-20, 007-CW, Carbowax, HP-Innowax, Rtx-WAX, ZB-WAX
◈ Ordering Information ID(mm) Length(m) Film(um) Temp Limits(°C) Part No. 0.10 20 0.20 20 to 240/250 127-7023FF 예일테크 2008.06.20
26
Agilent DB-WAX
DB-WAX
◈ Product Information
Agilent makes more capillary columns than anyone else in the world and our commitment to product reliability and repeatability has raised the level of quality that chromatographers demand. We continue to tighten our performance criteria such as separation efficiency, retention characteristics, peak height ratios, and bleed rates.
► Point
• Polyethylene glycol (PEG)
• Close equivalent to USP Phase G16
• High polarity
• Lower temperature limit of 20°C is lowest of any bonded PEG phase; improves resolution of low boiling point analytes
• Column-to-column repeatability
• Bonded and cross-linked; solvent rinsable
• Exact replacement of HP-WAX
► Similar Phases
- HP-20M, SUPELCOWAX 10, CP-WAX 52 CB, SUPEROX II, CB-WAX, Stabilwax, BP-20, 007-CW, Carbowax, HP-INNOWax, Rtx-WAX, ZB-WAX
◈ Ordering Information ID(mm) Length(m) Film(um) Temp Limits(°C) Part No. 0.05 10 0.05 20 to 250/260 126-7012 0.05 10 0.10 20 to 240/250 126-7013 0.10 10 0.10 20 to 250/260 127-7012 0.10 10 0.20 20 to 240/250 127-7013 0.10 20 0.10 20 to 250/260 127-7022 0.10 20 0.20 20 to 240/250 127-7023 0.18 10 0.18 20 to 250/260 121-7012 0.18 20 0.18 20 to 250/260 121-7022 0.18 20 0.30 20 to 240/250 121-7023 0.18 40 0.30 20 to 240/250 121-7043 0.20 25 0.20 20 to 250/260 128-7022 0.20 25 0.20 20 to 250/260 128-7032 0.20 50 0.20 20 to 250/260 128-7052 0.25 15 0.25 20 to 250/260 122-7012 0.25 15 0.50 20 to 240/250 122-7013 0.25 30 0.15 20 to 250/260 122-7031 0.25 30 0.25 20 to 250/260 122-7032 0.25 30 0.50 20 to 240/250 122-7033 0.25 60 0.15 20 to 250/260 122-7061 0.25 60 0.25 20 to 250/260 122-7062 0.25 60 0.50 20 to 240/250 122-7063 0.32 15 0.25 20 to 250/260 123-7012 0.32 15 0.50 20 to 240/250 123-7013 0.32 30 0.15 20 to 250/260 123-7031 0.32 30 0.25 20 to 250/260 123-7032 0.32 30 0.50 20 to 240/250 123-7033 0.32 60 0.25 20 to 250/260 123-7062 0.32 60 0.50 20 to 240/250 123-7063 0.45 30 0.85 20 to 230/240 124-7032 0.53 15 0.50 20 to 230/240 125-7017 0.53 15 1.00 20 to 230/240 125-7012 0.53 30 0.25 20 to 230/240 125-7031 0.53 30 0.50 20 to 230/240 125-7037 0.53 30 1.00 20 to 230/240 125-7032 0.53 60 1.00 20 to 230/240 125-7062 예일테크 2008.06.20
DB-WAX
◈ Product Information
Agilent makes more capillary columns than anyone else in the world and our commitment to product reliability and repeatability has raised the level of quality that chromatographers demand. We continue to tighten our performance criteria such as separation efficiency, retention characteristics, peak height ratios, and bleed rates.
► Point
• Polyethylene glycol (PEG)
• Close equivalent to USP Phase G16
• High polarity
• Lower temperature limit of 20°C is lowest of any bonded PEG phase; improves resolution of low boiling point analytes
• Column-to-column repeatability
• Bonded and cross-linked; solvent rinsable
• Exact replacement of HP-WAX
► Similar Phases
- HP-20M, SUPELCOWAX 10, CP-WAX 52 CB, SUPEROX II, CB-WAX, Stabilwax, BP-20, 007-CW, Carbowax, HP-INNOWax, Rtx-WAX, ZB-WAX
◈ Ordering Information ID(mm) Length(m) Film(um) Temp Limits(°C) Part No. 0.05 10 0.05 20 to 250/260 126-7012 0.05 10 0.10 20 to 240/250 126-7013 0.10 10 0.10 20 to 250/260 127-7012 0.10 10 0.20 20 to 240/250 127-7013 0.10 20 0.10 20 to 250/260 127-7022 0.10 20 0.20 20 to 240/250 127-7023 0.18 10 0.18 20 to 250/260 121-7012 0.18 20 0.18 20 to 250/260 121-7022 0.18 20 0.30 20 to 240/250 121-7023 0.18 40 0.30 20 to 240/250 121-7043 0.20 25 0.20 20 to 250/260 128-7022 0.20 25 0.20 20 to 250/260 128-7032 0.20 50 0.20 20 to 250/260 128-7052 0.25 15 0.25 20 to 250/260 122-7012 0.25 15 0.50 20 to 240/250 122-7013 0.25 30 0.15 20 to 250/260 122-7031 0.25 30 0.25 20 to 250/260 122-7032 0.25 30 0.50 20 to 240/250 122-7033 0.25 60 0.15 20 to 250/260 122-7061 0.25 60 0.25 20 to 250/260 122-7062 0.25 60 0.50 20 to 240/250 122-7063 0.32 15 0.25 20 to 250/260 123-7012 0.32 15 0.50 20 to 240/250 123-7013 0.32 30 0.15 20 to 250/260 123-7031 0.32 30 0.25 20 to 250/260 123-7032 0.32 30 0.50 20 to 240/250 123-7033 0.32 60 0.25 20 to 250/260 123-7062 0.32 60 0.50 20 to 240/250 123-7063 0.45 30 0.85 20 to 230/240 124-7032 0.53 15 0.50 20 to 230/240 125-7017 0.53 15 1.00 20 to 230/240 125-7012 0.53 30 0.25 20 to 230/240 125-7031 0.53 30 0.50 20 to 230/240 125-7037 0.53 30 1.00 20 to 230/240 125-7032 0.53 60 1.00 20 to 230/240 125-7062 예일테크 2008.06.20
25
Agilent DB-1701
DB-1701
◈ Product Information
Agilent makes more capillary columns than anyone else in the world and our commitment to product reliability and repeatability has raised the level of quality that chromatographers demand. We continue to tighten our performance criteria such as separation efficiency, retention characteristics, peak height ratios, and bleed rates.
► Point
• (14%-Cyanopropyl-phenyl)-methylpolysiloxane
• Low/midpolarity
• Bonded and cross-linked
• Exact replacement for HP-1701
• Solvent rinsable
• Available with DuraGuard (GC column with a built-in guard column)
► Similar Phases
- SPB-1701, CP-Sil 19 CB, Rtx-1701, BP-10, OV-1701, 007-1701, ZB-1701
◈ Ordering Information ID(mm) Length(m) Film(um) Temp Limits(°C) Part No. 0.10 20 0.10 -20 to 280/300 127-0722 0.10 20 0.40 -20 to 280/300 127-0723 0.18 10 0.40 -20 to 280/300 121-0713 0.25 15 0.25 -20 to 280/300 122-0712 0.25 15 1.00 -20 to 280/300 122-0713 0.25 30 0.15 -20 to 280/300 122-0731 0.25 30 0.25 -20 to 280/300 122-0732 0.25 30 1.00 -20 to 280/300 122-0733 0.25 60 0.15 -20 to 280/300 122-0761 0.25 60 0.25 -20 to 280/300 122-0762 0.25 60 0.50 -20 to 280/300 122-0766 0.25 60 1.00 -20 to 280/300 122-0763 0.32 15 0.25 -20 to 280/300 123-0712 0.32 15 1.00 -20 to 280/300 123-0713 0.32 30 0.15 -20 to 280/300 123-0731 0.32 30 0.25 -20 to 280/300 123-0732 0.32 30 1.00 -20 to 280/300 123-0733 0.32 50 1.00 -20 to 280/300 123-0753 0.32 60 0.25 -20 to 280/300 123-0762 0.32 60 1.00 -20 to 280/300 123-0763 0.53 15 1.00 -20 to 260/280 125-0712 0.53 30 0.25 -20 to 260/280 125-0731 0.53 30 0.50 -20 to 260/280 125-0737 0.53 30 1.00 -20 to 260/280 125-0732 0.53 30 1.50 -20 to 260/280 125-0733 0.53 60 1.00 -20 to 260/280 125-0762 예일테크 2008.06.20
DB-1701
◈ Product Information
Agilent makes more capillary columns than anyone else in the world and our commitment to product reliability and repeatability has raised the level of quality that chromatographers demand. We continue to tighten our performance criteria such as separation efficiency, retention characteristics, peak height ratios, and bleed rates.
► Point
• (14%-Cyanopropyl-phenyl)-methylpolysiloxane
• Low/midpolarity
• Bonded and cross-linked
• Exact replacement for HP-1701
• Solvent rinsable
• Available with DuraGuard (GC column with a built-in guard column)
► Similar Phases
- SPB-1701, CP-Sil 19 CB, Rtx-1701, BP-10, OV-1701, 007-1701, ZB-1701
◈ Ordering Information ID(mm) Length(m) Film(um) Temp Limits(°C) Part No. 0.10 20 0.10 -20 to 280/300 127-0722 0.10 20 0.40 -20 to 280/300 127-0723 0.18 10 0.40 -20 to 280/300 121-0713 0.25 15 0.25 -20 to 280/300 122-0712 0.25 15 1.00 -20 to 280/300 122-0713 0.25 30 0.15 -20 to 280/300 122-0731 0.25 30 0.25 -20 to 280/300 122-0732 0.25 30 1.00 -20 to 280/300 122-0733 0.25 60 0.15 -20 to 280/300 122-0761 0.25 60 0.25 -20 to 280/300 122-0762 0.25 60 0.50 -20 to 280/300 122-0766 0.25 60 1.00 -20 to 280/300 122-0763 0.32 15 0.25 -20 to 280/300 123-0712 0.32 15 1.00 -20 to 280/300 123-0713 0.32 30 0.15 -20 to 280/300 123-0731 0.32 30 0.25 -20 to 280/300 123-0732 0.32 30 1.00 -20 to 280/300 123-0733 0.32 50 1.00 -20 to 280/300 123-0753 0.32 60 0.25 -20 to 280/300 123-0762 0.32 60 1.00 -20 to 280/300 123-0763 0.53 15 1.00 -20 to 260/280 125-0712 0.53 30 0.25 -20 to 260/280 125-0731 0.53 30 0.50 -20 to 260/280 125-0737 0.53 30 1.00 -20 to 260/280 125-0732 0.53 30 1.50 -20 to 260/280 125-0733 0.53 60 1.00 -20 to 260/280 125-0762 예일테크 2008.06.20
24
Agilent DB-1301
DB-1301
◈ Product Information
Agilent makes more capillary columns than anyone else in the world and our commitment to product reliability and repeatability has raised the level of quality that chromatographers demand. We continue to tighten our performance criteria such as separation efficiency, retention characteristics, peak height ratios, and bleed rates.
► Point
• (6%-Cyanopropyl-phenyl)-methylpolysiloxane
• Equivalent to USP Phase G43
• Low/midpolarity
• Bonded and cross-linked
• Solvent rinsable
• Exact replacement of HP-1301
► Similar Phases
- Rtx-1301, PE-1301
◈ Ordering Information ID(mm) Length(m) Film(um) Temp Limits(°C) Part No. 0.25 30 0.25 -20 to 280/300 122-1332 0.25 30 1.00 -20 to 280/300 122-1333 0.25 60 0.25 -20 to 280/300 122-1362 0.25 60 1.00 -20 to 280/300 122-1363 0.32 30 0.25 -20 to 280/300 123-1332 0.32 30 1.00 -20 to 280/300 123-1333 0.32 60 1.00 -20 to 280/300 123-1363 0.53 15 1.00 -20 to 260/280 125-1312 0.53 30 1.00 -20 to 260/280 125-1332 0.53 30 1.50 -20 to 260/280 125-1333 예일테크 2008.06.20
DB-1301
◈ Product Information
Agilent makes more capillary columns than anyone else in the world and our commitment to product reliability and repeatability has raised the level of quality that chromatographers demand. We continue to tighten our performance criteria such as separation efficiency, retention characteristics, peak height ratios, and bleed rates.
► Point
• (6%-Cyanopropyl-phenyl)-methylpolysiloxane
• Equivalent to USP Phase G43
• Low/midpolarity
• Bonded and cross-linked
• Solvent rinsable
• Exact replacement of HP-1301
► Similar Phases
- Rtx-1301, PE-1301
◈ Ordering Information ID(mm) Length(m) Film(um) Temp Limits(°C) Part No. 0.25 30 0.25 -20 to 280/300 122-1332 0.25 30 1.00 -20 to 280/300 122-1333 0.25 60 0.25 -20 to 280/300 122-1362 0.25 60 1.00 -20 to 280/300 122-1363 0.32 30 0.25 -20 to 280/300 123-1332 0.32 30 1.00 -20 to 280/300 123-1333 0.32 60 1.00 -20 to 280/300 123-1363 0.53 15 1.00 -20 to 260/280 125-1312 0.53 30 1.00 -20 to 260/280 125-1332 0.53 30 1.50 -20 to 260/280 125-1333 예일테크 2008.06.20
내용이 없습니다.